{"id":2724,"date":"2016-01-17T14:32:03","date_gmt":"2016-01-17T19:32:03","guid":{"rendered":"https:\/\/infotechguy.net\/?p=2724"},"modified":"2022-08-26T09:45:44","modified_gmt":"2022-08-26T13:45:44","slug":"replacing-8x-rbc43-batteries-in-a-apc-sua3000rm2u-ups","status":"publish","type":"post","link":"https:\/\/infotechguy.net\/?p=2724","title":{"rendered":"APC UPS &#8212; Replacing RBC43 Batteries in a SUA3000RM2U UPS"},"content":{"rendered":"<p>So it finally happened. The Batteries in my<strong> APC SUA3000RM2U<\/strong> finally went bad. I&#8217;ve had them for over 5 years so I am happy with there life. I&#8217;ve had to replace UPS Battery Cartridges and Packs before when working as a Data Center consultant. It is usually a simple and straight forward task. I would RMA the Battery Cartridge or Pack, if it&#8217;s under warranty, and then the\u00a0manufacturer would send me back a new Battery Cartridge or Pack already filled with new batteries. Hot swap it with the old one and you are done.<\/p>\n<p>However, this time it was my home unit and I don&#8217;t have warranty coverage or the extended one(usually purchased by an enterprise). So I went online looking for a Battery Cartridge replacement, <strong><a href=\"http:\/\/www.amazon.com\/APC-RBC43-Replacement-SUM1500RMXL2U-SUM3000RMXL2U\/dp\/B0002DOEOI\/ref=sr_1_2?s=electronics&amp;ie=UTF8&amp;qid=1453059050&amp;sr=1-2&amp;keywords=sua3000rm2u\" target=\"_blank\" rel=\"noopener noreferrer\">$300-400!!!, o my<\/a>!<\/strong> So I decided to try and replace the batteries themselves rather than the entire Battery Cartridge. I was able to find a pack of <a href=\"http:\/\/www.replaceupsbattery.com\/UPS-Batteries\/APC-SMART-UPS-RM-SUA3000RM2U-Batteries-Set-of-8\/?utm_campaign=map&amp;utm_medium=email&amp;utm_source=yotpo&amp;yotpo_token=b2aa2cf083435e8c8f760275314c72655df4d3ae\" target=\"_blank\" rel=\"noopener noreferrer\"><strong>8 batteries for around $83<\/strong><\/a> with free expedite shipping. The following steps were what I did to replace each APC RBC43 battery inside the battery cartridge.<\/p>\n<ol>\n<li style=\"list-style-type: none;\">\n<ol>\n<li>\n<h6>Tools needed, New Batteries, Sharpie, Phillips Screwdriver, Utility knife(was in picture for cutting the new box of batteries open only, haha).<\/h6>\n<p><a href=\"https:\/\/infotechguy.net\/wp-content\/uploads\/2021\/03\/20160116-1527571-scaled-1.jpg\"><img loading=\"lazy\" decoding=\"async\" class=\" wp-image-3325 aligncenter\" src=\"https:\/\/infotechguy.net\/wp-content\/uploads\/20160116-1527571-169x300.jpg\" alt=\"\" width=\"307\" height=\"545\" \/><\/a><\/li>\n<\/ol>\n<\/li>\n<\/ol>\n<p><!--more--><\/p>\n<ul>\n<li>\n<h6>Identified the &#8220;Replace Battery Indicator&#8221; is red, and proceed to remove the APC units bezel<\/h6>\n<p><a href=\"https:\/\/infotechguy.net\/wp-content\/uploads\/2021\/03\/20160116-143752-scaled-1.jpg\"><img loading=\"lazy\" decoding=\"async\" class=\"alignnone wp-image-3327\" src=\"https:\/\/infotechguy.net\/wp-content\/uploads\/20160116-143752-300x169.jpg\" alt=\"\" width=\"600\" height=\"338\" \/><\/a><\/li>\n<li>\n<h6>Disconnect the Battery Cartridge Power Supply Connector from the main APC unit. The unit will begin to beep and the Replace Battery indicator will being to flash continuously.<\/h6>\n<p><a href=\"https:\/\/infotechguy.net\/wp-content\/uploads\/2021\/03\/20160116-143842-scaled-1.jpg\"><img loading=\"lazy\" decoding=\"async\" class=\"alignnone wp-image-3328\" src=\"https:\/\/infotechguy.net\/wp-content\/uploads\/20160116-143842-300x169.jpg\" alt=\"\" width=\"600\" height=\"338\" \/><\/a><\/li>\n<li>\n<h6>\u00a0Locate the 3 Battery Cartridge fastener screws and remove them.<br \/>\n<a href=\"https:\/\/infotechguy.net\/wp-content\/uploads\/2021\/03\/20160116-144515-scaled-1.jpg\"><img loading=\"lazy\" decoding=\"async\" class=\"alignnone wp-image-3329\" src=\"https:\/\/infotechguy.net\/wp-content\/uploads\/20160116-144515-300x169.jpg\" alt=\"\" width=\"600\" height=\"338\" \/><\/a><\/h6>\n<\/li>\n<li>\n<h6>Remove the Battery Cartridge and set it down on\u00a0 a table, careful!! it weighs 40 lbs!! Remove the 4 screws holding the top plate on the Battery Cartridge.<\/h6>\n<p><a href=\"https:\/\/infotechguy.net\/wp-content\/uploads\/2021\/03\/20160116-1454501-scaled-1.jpg\"><img loading=\"lazy\" decoding=\"async\" class=\"alignnone wp-image-3330\" src=\"https:\/\/infotechguy.net\/wp-content\/uploads\/20160116-1454501-169x300.jpg\" alt=\"\" width=\"350\" height=\"621\" \/><\/a> <a href=\"https:\/\/infotechguy.net\/wp-content\/uploads\/2021\/03\/20160116-1457501-scaled-1.jpg\"><img loading=\"lazy\" decoding=\"async\" class=\"alignnone wp-image-3331\" src=\"https:\/\/infotechguy.net\/wp-content\/uploads\/20160116-1457501-169x300.jpg\" alt=\"\" width=\"350\" height=\"621\" \/><\/a><\/li>\n<li>\n<h6>Rotate the first row of batteries(2ea) to expose their terminals.<\/h6>\n<p><a href=\"https:\/\/infotechguy.net\/wp-content\/uploads\/2021\/03\/20160116-145922-1-scaled-1.jpg\"><img loading=\"lazy\" decoding=\"async\" class=\"wp-image-3333 aligncenter\" src=\"https:\/\/infotechguy.net\/wp-content\/uploads\/20160116-145922-1-169x300.jpg\" alt=\"\" width=\"350\" height=\"621\" \/><\/a><\/li>\n<li>\n<h6>Mark each Positive lead with a Sharpie to keep track of the cabling<\/h6>\n<p><a href=\"https:\/\/infotechguy.net\/wp-content\/uploads\/2021\/03\/20160116-150223-1-scaled-1.jpg\"><img loading=\"lazy\" decoding=\"async\" class=\"wp-image-3334 aligncenter\" src=\"https:\/\/infotechguy.net\/wp-content\/uploads\/20160116-150223-1-169x300.jpg\" alt=\"\" width=\"350\" height=\"621\" \/><\/a><\/li>\n<li>\n<h6>Remove one battery to compare the old battery with the new. Double check their specifications match and you received the correct replacement ones.<br \/>\n<a href=\"https:\/\/infotechguy.net\/wp-content\/uploads\/2021\/03\/20160116-150817-scaled-1.jpg\"><img loading=\"lazy\" decoding=\"async\" class=\"wp-image-3335 aligncenter\" src=\"https:\/\/infotechguy.net\/wp-content\/uploads\/20160116-150817-300x169.jpg\" alt=\"\" width=\"350\" height=\"197\" \/><\/a><\/h6>\n<\/li>\n<li>\n<h6>\u00a0Replace each of the two(2) batteries in the first row with the new batteries. Do one row at a time!!<\/h6>\n<p><a href=\"https:\/\/infotechguy.net\/wp-content\/uploads\/2021\/03\/20160116-150451-scaled-1.jpg\"><img loading=\"lazy\" decoding=\"async\" class=\" wp-image-3336 aligncenter\" src=\"https:\/\/infotechguy.net\/wp-content\/uploads\/20160116-150451-169x300.jpg\" alt=\"\" width=\"350\" height=\"621\" \/><\/a><\/li>\n<li>\n<h6>Reset the batteries carefully, there are metal notches to keep them from moving too freely, and make sure you tuck in the the wires so the battery is flush on the metal surface.<\/h6>\n<p><a href=\"https:\/\/infotechguy.net\/wp-content\/uploads\/2021\/03\/20160116-150635-scaled-1.jpg\"><img loading=\"lazy\" decoding=\"async\" class=\"wp-image-3337 aligncenter\" src=\"https:\/\/infotechguy.net\/wp-content\/uploads\/20160116-150635-169x300.jpg\" alt=\"\" width=\"351\" height=\"623\" \/><\/a><\/li>\n<li>\n<h6>Move on to the next rows, do them one row at a time.<\/h6>\n<p><a href=\"https:\/\/infotechguy.net\/wp-content\/uploads\/2021\/03\/20160116-150941-scaled-1.jpg\"><img loading=\"lazy\" decoding=\"async\" class=\"alignnone wp-image-3338\" src=\"https:\/\/infotechguy.net\/wp-content\/uploads\/20160116-150941-169x300.jpg\" alt=\"\" width=\"350\" height=\"621\" \/><\/a> <a href=\"https:\/\/infotechguy.net\/wp-content\/uploads\/2021\/03\/20160116-150738-scaled-1.jpg\"><img loading=\"lazy\" decoding=\"async\" class=\"alignnone wp-image-3339\" src=\"https:\/\/infotechguy.net\/wp-content\/uploads\/20160116-150738-169x300.jpg\" alt=\"\" width=\"350\" height=\"621\" \/><\/a><\/li>\n<li>\n<h6>Almost done!<\/h6>\n<p><a href=\"https:\/\/infotechguy.net\/wp-content\/uploads\/2021\/03\/20160116-151510-scaled-1.jpg\"><img loading=\"lazy\" decoding=\"async\" class=\"wp-image-3340 aligncenter\" src=\"https:\/\/infotechguy.net\/wp-content\/uploads\/20160116-151510-169x300.jpg\" alt=\"\" width=\"350\" height=\"622\" \/><\/a><\/li>\n<li>\n<h6>Inspect each row to ensure that the leads haven&#8217;t lose and each battery is flat and flush. Put the metal cover tray back on the Battery Cartridge and screw each of the 4 fastener screws.<\/h6>\n<p><a href=\"https:\/\/infotechguy.net\/wp-content\/uploads\/2021\/03\/20160116-151631-scaled-1.jpg\"><img loading=\"lazy\" decoding=\"async\" class=\"alignnone wp-image-3341\" src=\"https:\/\/infotechguy.net\/wp-content\/uploads\/20160116-151631-169x300.jpg\" alt=\"\" width=\"350\" height=\"622\" \/><\/a> <a href=\"https:\/\/infotechguy.net\/wp-content\/uploads\/2021\/03\/20160116-151804-scaled-1.jpg\"><img loading=\"lazy\" decoding=\"async\" class=\"alignnone wp-image-3342\" src=\"https:\/\/infotechguy.net\/wp-content\/uploads\/20160116-151804-169x300.jpg\" alt=\"\" width=\"350\" height=\"622\" \/><\/a><\/li>\n<li>\n<h6>Replace the Battery Cartridge back into the APC unit, Reconnect the Battery Cartridge Power Supply, and Re-Fasten the 3 fastener screws for the Battery Cartridge.<\/h6>\n<p><a href=\"https:\/\/infotechguy.net\/wp-content\/uploads\/2021\/03\/asf-scaled-1.jpg\"><img loading=\"lazy\" decoding=\"async\" class=\"wp-image-3343 aligncenter\" src=\"https:\/\/infotechguy.net\/wp-content\/uploads\/asf-300x169.jpg\" alt=\"\" width=\"600\" height=\"338\" \/><\/a><\/p>\n<p>&nbsp;<\/li>\n<li>\n<h6>Ensure the Replace Battery indicator has stopped blinking and the APC unit has stopped beeping. This will ensure that their is no wiring issues or shorts in the Battery Cartridge.<\/h6>\n<\/li>\n<li>Press and Hold the Test(I) button for 3 seconds. The unit will kick over to Battery mode and test the new Batteries<br \/>\n<a href=\"https:\/\/infotechguy.net\/wp-content\/uploads\/2021\/03\/20160116-152416-1-scaled-1.jpg\"><img loading=\"lazy\" decoding=\"async\" class=\"wp-image-3344 aligncenter\" src=\"https:\/\/infotechguy.net\/wp-content\/uploads\/20160116-152416-1-300x169.jpg\" alt=\"\" width=\"600\" height=\"338\" \/><\/a><\/li>\n<li>\n<h6>If all goes well, the Replace Battery red indicator should turn off, give the unit a few hours to charge, and you should be all set!! Don&#8217;t for get to put the Bezel back on, haha.<\/h6>\n<p><a href=\"https:\/\/infotechguy.net\/wp-content\/uploads\/2021\/03\/20160116-152501-1-scaled-1.jpg\"><img loading=\"lazy\" decoding=\"async\" class=\"wp-image-3345 aligncenter\" src=\"https:\/\/infotechguy.net\/wp-content\/uploads\/20160116-152501-1-300x169.jpg\" alt=\"\" width=\"600\" height=\"338\" \/><\/a><\/li>\n<li>\n<h6>All done!!<\/h6>\n<p><a href=\"https:\/\/infotechguy.net\/wp-content\/uploads\/2021\/03\/20160116-152545-1-scaled-1.jpg\"><img loading=\"lazy\" decoding=\"async\" class=\"wp-image-3346 aligncenter\" src=\"https:\/\/infotechguy.net\/wp-content\/uploads\/20160116-152545-1-300x169.jpg\" alt=\"\" width=\"600\" height=\"338\" \/><\/a><\/li>\n<\/ul>\n<p>&nbsp;<\/p>\n<p>&nbsp;<\/p>\n<p>&nbsp;<\/p>\n","protected":false},"excerpt":{"rendered":"<p>So it finally happened. The Batteries in my APC SUA3000RM2U finally went bad. I&#8217;ve had them for over 5 years so I am happy with there life. I&#8217;ve had to replace UPS Battery Cartridges and&#46;&#46;&#46;<\/p>\n","protected":false},"author":2,"featured_media":4279,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[1],"tags":[132],"class_list":["post-2724","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-uncategorized","tag-hardware"],"_links":{"self":[{"href":"https:\/\/infotechguy.net\/index.php?rest_route=\/wp\/v2\/posts\/2724","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/infotechguy.net\/index.php?rest_route=\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/infotechguy.net\/index.php?rest_route=\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/infotechguy.net\/index.php?rest_route=\/wp\/v2\/users\/2"}],"replies":[{"embeddable":true,"href":"https:\/\/infotechguy.net\/index.php?rest_route=%2Fwp%2Fv2%2Fcomments&post=2724"}],"version-history":[{"count":1,"href":"https:\/\/infotechguy.net\/index.php?rest_route=\/wp\/v2\/posts\/2724\/revisions"}],"predecessor-version":[{"id":4147,"href":"https:\/\/infotechguy.net\/index.php?rest_route=\/wp\/v2\/posts\/2724\/revisions\/4147"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/infotechguy.net\/index.php?rest_route=\/wp\/v2\/media\/4279"}],"wp:attachment":[{"href":"https:\/\/infotechguy.net\/index.php?rest_route=%2Fwp%2Fv2%2Fmedia&parent=2724"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/infotechguy.net\/index.php?rest_route=%2Fwp%2Fv2%2Fcategories&post=2724"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/infotechguy.net\/index.php?rest_route=%2Fwp%2Fv2%2Ftags&post=2724"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}